Sunday, March 22, 2009

500kV Refresher Training Part 2


Location : Ayer Tawar, Perak


Duration : 9th - 13th March 2009



The second session of our 500kV refresher training was held in Ayer Tawar, Perak. We pass by this place on the way to Lumut. The roads are now wider compared to few years back and drivers will feel safe using this road in any purposes. This second session of training was more challenging because we were dealing with energized transmission line.



Our meeting point was in Ayer Tawar substation where we would carry out the morning briefing and discussion regarding the work and tasks which has to be done for the day. The red and white painted structure is the transmission tower and those gigantic pillars are the busbars. The power will pass by the busbars, breakers, isolators and transformers before it could be distributed to the customers and industrial zones.





Part of the training was to replace upper string insulators at this tower. This tower carries the voltage of 500kV from Ayer Tawar to Junjung.It is a ST type tower and the angle of the tower is 45 degrees. Photos displayed below shows the process of and progress of replacing the insulators.



Handlines being placed and measurements are taken to ensure the appropriate location to assemble the boom. Boom is an assembly of 4 poles which will play the role of being like crane to hoist up the craddle and lower it down.







The final part of assemblying the boom is mounting the Gin Boom. The length of this Gin Boom is 19 feet and it plays the important role of controlling the craddle.



Boom assembly is completed and final checks being done to ensure the Boom is safe.







Lineman in position and waiting for the next task which is mounting the ladder. The 24 feet ladder will be mounted parrallel with the conductor in order to send hotmen to approach the 'live' conductor.




Ladder mounting in progress. There are two ways for hotmen to approach the conductor. One is by assemblying ladder and the other is by rope access where only insulated ropes used to swing hotmen towards the conductors. In this case, we decided to assemble the ladder.






The ladder will be hoisted up in level with the conductors by using 2/3 rope blocks and two control ropes will be tied both sides of the ladder to swing the ladder to left and right.







Aerial view of Boom from the tower.








Here is the hotmen in his position to start the task of replacing the insulators.



The arching horn has to be removed in order to mount the yoke which will be attached with strain poles to remove the insulator socket from it's clevis.



The dismantled arching horn will be lowered to the ground and will be fixed upon completion of the task.





Craddle been hoisted up and the process of changing insulators in progress.



The insulators has removed from the clevis and its ready to be replaced with the new insulators. The insulators prevent the current from flowing to the body of the tower and tests have to be done before replacing the insulators.

Sunday, March 8, 2009

500 kV Refresher Training



Location : Malim Nawar, Perak.
Duration : 3rd March - 7th March 2009.

500kV transmission towers are the largest power carriage in Malaysia.The objective of this training is to improve our skills and effiency as this training works as a refresher course for our team. This training is conducted as we hardly do maintenance at 500kV transmission towers. The height of this 500kV towers can reach up to 100 metres. These towers are also considered as sky scrappers for the height they posses. Seen below are some photos taken during the first phase of this training.

Rescuing from conductor is one of the practice which is compulsary and every lineman in live line unit should know so that it can be very useful in case of emergency.

Victim being lowered to ground by using rope.

One of the stunts exhibited by our trainer Zul Fly lowering to the ground by himself.

Victim being rescued by giving CPR.

===========================================================================

Changing tension tower insulators [upper string]

All the tools and ropes have to be tested before the task could be carried out. Ropes and hotsticks are tested by using rope and pole tester. The hotsticks must be wiped with silicone cloth to avoid the moisture to peneterate through it.

Handline being installed to hoist up tools and poles. Lineman are in position to start the task.

Lineman are busy mounting the brackets and ropes for assemblying BOOM and Ladder.


BOOM installing in progress.


BOOM and Ladder installed.



Overall view at work site.


Final checks before hoisting craddle.

The process of changing insulators in progress.

The insulators being removed and replaced with the new one.


The next phase of training to be conducted in Sitiawan where we will be exposed in energized line.I will put up the recap of the second phase training once its completed.